General Radio 1608-A Impedance Bridge # O45

EUR 285,00 Achat immédiat ou Offre directe, EUR 32,00 Livraison, 14-Jour Retours, Garantie client eBay
Vendeur: f1power01 ✉️ (11.035) 99.2%, Lieu où se trouve: Dornes, FR, Lieu de livraison: WORLDWIDE, Numéro de l'objet: 314085815498 GENERAL RADIO 1608-A IMPEDANCE BRIDGE # O45.

GENERAL RADIO 1608-A
IMPEDANCE BRIDGE

Sold AS-IS - No test

RANGES
Capacitance: 0.05 pf to 1100 ,..r in seven ranges, series or parallel.
Inductance: 0.05 l'h to 1100 h in seven ranges, series or parallel.
Resistance: (series) 0.05 milliohm to 1.1 megohms, ac or de.
Conductance: (parallel) 0.05 nanomhos to 1.1 mhos, ac or de (20,000
megohms to 0.9 ohm).
0: (of series capacitance)- 0.0005 to 1 at 1 kc.
(of parallel capacitance) - 0.02 to 2 at 1 kc.
Q: (of series inductance)-· 0.5 to 50 at 1 kc.
(of parallel inductance)- 1 to 2000 at 1 kc.
(of series resistance)- 0.0005 to 1.2 inductive at 1 kc.
(of parallel conductance)- 0.0005 to 1.2 capacitive at 1 kc.
Frequency: 1 kc with internal oscillator module supplied; 20 cps to
20 kc with external oscillator.
ACCURACY
C, G, R, L
At 1 kc: ± 0.1% ± 0.005% of full scale except on lowest R and L
ranges and highest C and Granges, where it is ±0.2% ± 0.005% of
full scale.
Additional % error terms for high frequency and large phase angle:
C and L: ( ±0.001fi, ± 0.11Jfkc ::':: 0.5/)2)'/n of measured quantity.
Rand G: (±0.002Ji, ±O.OOOOOIJZ, ±0.1Q)%ofmeasuredquantity.
Residual Terminal Impedance: H ~ 0.001 ohm, L ~ 0.15 l'h, C ~ 0.25
pf.
DC Resistance and Conductance: Same m; for I-ke measurement, except
that accuracy b limited by sensitivity at the ran~~:e extremes. Balances
to 0.1% are possible from 1 ohm to 1 megohm with the internal
supply and detector.
D (or~) of Cor L: ±0.0005 ± 5% at I kc or lower.
±0.0005fkc ± 5% above 1 kc.
Q of R or G: ±0.0005fk, ± 2%.
GENERATOR AND DETECTOR
Internal Oscillator: 1 kc ± 1% normally supplied. Plug-in modules
for other frequencies available on request. Level control provided.
Internal AC Detector: Can be used either flat or selective at frequency
of plug-in module (normally 1 kc). Second-harmonic rejection approx-
imately 25 db; sensitivity control provided.
Internal DC Supplies: 3.5 volts, 35 volts, 350 volts, adjustable, and
power limited to less than Ya watt.
External Oscillator and Detector: For measurement at othE>r frequencies
from 20 cps to 20 kc, TYPE 1210-C Unit l{-C Oscillator, che TYPJo;
1311-A Audio Oscillator, and TYPE 1232-A Tuned Amplifier and
~ull Detector are recommended.
DC Bias: Provision is made for biasing capacitors to 500 volts with
external supplies, and for biasing current in inductors.
GENERAL
Accessories Supplied: TYPE CAP-22 Power Cord, spare fuses, spare
indicator lamps.
Accessories Available: TYPE 1650-Pl Test Jig (page 35); external
generator and detector, if used, as listed above.
Power Requirements: 105 to 125 (or 210 to 250) volts, 50 to 60 cps,
10 watts.

Vendu seul – sans cordon

VENDU SANS CABLE

***

Livraison par transporteur :

Matériel vendu avec facture Equipment sold with invoice

  • Condition: Pour pièces détachées/ne fonctionne pas
  • Condition: Sold AS-IS
  • Objet modifié: Non
  • Produit étranger: Non
  • Type de Mesures, Tests: BRIDGE
  • Type: Mesure,Test
  • Offre groupée personnalisée: Non
  • Marque: GENERAL

PicClick Insights - General Radio 1608-A Impedance Bridge # O45 PicClick Exclusif

  •  Popularité - 9 personnes suivent la vente, 0.0 de nouvelles personnes suivent la vente par jour, 612 days for sale on eBay. Super grande quantité suivi. 0 vendu, 1 disponible.
  •  Meilleur Prix -
  •  Vendeur - 11.035+ articles vendu. 0.8% évaluations négative. Grand vendeur avec la très bonne rétroaction positive et plus de 50 cotes.

Les Gens ont Aussi Aimé PicClick Exclusif