MS400 simulatormulti-paramètre Simulator patient, simulateur ECG NIBP

EUR 478,80 Achat immédiat ou Offre directe, Livraison gratuite, Garantie client eBay
Vendeur: healthcare_home ✉️ (901) 97.3%, Lieu où se trouve: 28197 Bremen, DE, Lieu de livraison: WORLDWIDE, Numéro de l'objet: 186143286094 MS400 simulatormulti-paramètre Simulator patient, simulateur ECG NIBP.

MS400 Multiparameter Simulator  Introduction  MS400 Multiparameter Simulator is a portable device, features in small volume and light weight. It can simulate accurately 12-lead ECG, Respiration, Temperature, 2-channel IBP or 4-channel IBP. And it can be tested in where the monitor is used.
Functions Simulate 35 kinds of arrhythmia (including Atrial, Ventricular, Premature Beat and Conduction Defects) and pacemaker waveforms (including Asynchronous, Demand Occ Sinus, Demand Freq Sinus, A/V Sequential, Non Capture, Non Function). Simulate four-channel IBP data. Simulate respiration signal with adjustable respiration rate, impedance and baseline impedance, and three kinds of apnea data. Simulate four kinds of temperature data. Simulate square wave, triangle wave, pulse wave and sine wave with adjustable frequency. Simulate standard ECG calibration, adult and pediatric ECG signal. ECG waveform complied with the standard of ANSI/AAMI EC13-2002, AHA, MIT ECG database, other ECG database and user-defined waveform data stored in TF card can be displayed by the simulator and exported to the equipments to be tested. Each waveform can be displayed by sliding the 3.5'' TFT touch screen, easy to operate. Power supply: rechargeable lithium battery or linear adapter, which reduces interference. Optional operation modes: keys and touch screen.
Performance 1)ECG Conventional All leads have the same voltage with the II-lead as the reference Amplitude 0.5,1.0,1.5 and 2.0mV ECG Rate 15,20,25,30,40,60,80,100,120,140,160, 180,200,220,240,260,280,300,320,340and 350 BPM ECG artifacts 50 and 60 Hz, muscle, baseline and breathing The elevation of the ST segment +0.8 to -0.8 mV, the step is 0.1 mV 2)Arrhythmia Atrial Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus  Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm,  Supraventricular Tachycardia Ventricular Vent Fib (coarse), Vent Fib (fine), PVCs 6/min, PVCs 12/min,  PVCs 24/min,  Frequent Multifocal, Bigeminy, Trigeminy,  Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia,  Asystole Premature Beat Atrial PAC, Nodal PNC, PVC1 LV Focus, PVC1 E LV Focus, R  on T LV Focus,PVC2 RV Focus, PVC2 E RV Focus, R on T RV  Focus, Multifocal PVC Conduction Defects First Degree Heart Block, Second Degree Heart Block, Third  Degree Heart Block, Right Bundle Branch Block, Left Bundle  Branch Block. 3)Four IBP Channels The default 00/00mmHg Dynamic IBP(unit: mmHg) Channel 1 Artery 120/80 Radial 120/80 Left Ventricle 120/00 Right Ventricle 25/00 Channel 2 Artery 120/80 Radial 120/80 Left Ventricle 120/00 Right Atrium(CVP) 15/10 Right Ventricle 25/00 Pulmonary Artery 25/10 Pulmonary Wedge 10/2 Left Atrium 4/4 Channel 3 Artery 120/80 Radial 120/80 Left Ventricle 120/00 Right Atrium(CVP) 15/10 Right Ventricle 25/00 Pulmonary Artery 25/10 Pulmonary Wedge 10/2 Left Atrium 14/4 Channel 4: Auto Swan-Ganz (every 15 seconds) RA(CVP), RV, PA, PAW (Pulmonary Wedge) Man Swan-Ganz press ENTER key to change every time Static-Pressure Levels Channel 1 0, 80, 160, 240, 320 and 400mmHg Channel 2 0, 50, 100, 150, 200 and 250mmHg Channel 3 0, 20, 40, 60, 80 and 100mmHg Channel 4 P4 tracks the static pressure levels of P3 4)Respiration Respiration Rate 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIN Impedance 0.2, 0.5, 1.0 and 3.0 Ω Baseline impedance 500, 1000, 1500, 2000Ω Apnea 12 s, 22 s, 32 s 5)Temperature  Four temperature 0℃(32°F), 24℃( 75°F), 37℃(98.6°F), 40℃(104°F)
Accessories Standard accessories 9V/1A(CE) power adapter, an User manual, a packaging box, a  plastic packaging. Optional accessories a  power adapter(15V/1A)(UL), a power adapter(15V/1A),a  temperature cable,an IBP cable, a CD disk(including a case  conversion software)
  • Condition: Neuf
  • Type de machine: Holter-ECG
  • Nombre de canaux: 12

PicClick Insights - MS400 simulatormulti-paramètre Simulator patient, simulateur ECG NIBP PicClick Exclusif

  •  Popularité - 0 personnes suivent la vente, 0.0 de nouvelles personnes suivent la vente par jour, 150 days for sale on eBay. 0 vendu, 10 disponibles.
  •  Meilleur Prix -
  •  Vendeur - 901+ articles vendu. 2.7% évaluations négative. Bon vendeur avec bonne rétroaction positive et bonne quantité de cotes.

Les Gens ont Aussi Aimé PicClick Exclusif